*********UNDER DEVELOPMENT (IMAGES REQUIRED)************
STEP 1
Reset boiler and wait for diverter valve motor to activate and stop. The valve will now be in heating mode with arm extended (the default position). NOTE: if this step is not correcly followed you will not be able to remove the motor in step 4.
STEP 2
Close both service valves and drain down boiler
STEP 3
Remove the 2 diverter valve retaining screws (not the screws holding the motor in position if there are any) twist and pull out the old cartridge. Retain the 2 screws to fit the new cartridge.
Clean inside the diverter valve body.
STEP 4
Remove the motor from the valve and retain for re-use
STEP 5
Lubricate the 2 external O rings on the Fit Once(tm) cartridge and then push very firmly to fit in place. Fix in with the 2 retaining screws you removed earlier.
STEP 6
Now check the Fit Once(tm) cartridge internal seal is in the open position. Using the service tool (black plastic tube) with a screwdriver attached, mate with the cartridge teeth and chack the slot on the service tool is in the vertical position.
STEP 7
Fit the motor and turn on to draw it into the valve body and the power off. With the motor held into position like this it is now easier to fit the 2 motor retainers with the screws provided. The one retainer with a cut out should be fitted on the right.
STEP 8
Power on bolier, purge air from boiler and test heating and hot water.