The following instructions apply to:
- ecoTEC plastic and brass valves (0020020015 & 0020132684)
- Glow-worm 0020014168
STEP 1
Reset boiler and wait for motor to activate – the motor arm will retract, pause and then extend. The valve will now be in heating mode with arm extended (the default position). Remove retaining nut and unhook motor arm from cartridge steel pin.

STEP 2
Mate the service tool with the Fit Once™ cartridge Note: the teeth on the service tool are irregular and will only mate with the cartridge in one position. The slot on the service tool should be at 12o’c (the operational position) when engaged.

Turn the service tool ANTI-CLOCKWISE until you meet some resistance (about the 7o’c position). This is the service position.

STEP 3
Reverse the service tool and mate with the canister seal. Turn by hand ANTI-CLOCKWISE and remove the canister seal.

STEP 4
Lubricate the the replacement external O ring on the canister with silicone grease and place some grease inside the hole at the bottom of the canister.
Fit the replacement canister to the service tool and insert over the cartidge pin and tighten.
STEP 5
Reverse the service tool and mate with the cartridge. Turn the service tool CLOCKWISE to return the slot to the upright position. Note: when following step 4, tightening the canister seal may have also turned the cartridge into its correct operational position.
STEP 6
Refit motor and test boiler heating and hot water function.
STEP 7
Complete next service date sticker and fix as shown below. Providing the system water is clean and a magnetic filter is fitted, the seals should be replaced every 4 years.